In step 1 give the introduction of the concept and in step 2 give the correct answer and give its explanation seperately and in step 3 explain why the other options are not correct and give final answer at last explain what we did in each step in just few sentences use formula andcalculation for beter understanding1) When the receiver in previous question is tured to 540 kHz station, what other AM station offers potential interference? 285 kHz 1)995 kHz ©1060 kHz d) 1450 kHz 2) An industrial plant is served by a 12470.v deta/430-v gronded-wye transformer. The high voltage ide of the transformer is served from a 12470-v wye.connected distribution line that has a grounded neutral. The best protection of th transformer against lightning strikes on the 12470.v ine il result from surge arrester connections of 2) Phase to ground on the 12470-v ide of th transformer b) Phase to phase on the 12470.v side ofthe transformer ©) Balise:to ground on the 430-v side of the transformer ) Phase to neutral to ground on the 430-v sce ofthe transformer 3) ASCADA system configuration regires maximum values (Le. the actual value of current when the transducer is at full scale). The transducer ah a flscale ac current of 5A. Sing a current transformer it a ts ait of 40035. the maximum current value (amperes) is most nearly a) 1200 b)800 400 4300 4) Whats the maximum allowable size of the over-current device normaly alowed to protect an AWG # 12. THHW conductor rated for 90° sed in an ambient temperature of 55°C? Only standard size over —current devices are available a0 b)15 920 30 5) When using the method of symmetrical components , which of the following statements is most nearly correct 2) The three zero.sequence current phasors are equal in magnitude and displaced by 1200 1b) The three positive=sequence and the three negative-sequence current phases are all equal in ‘mannitude_ but have opposite phase ©)In a wye-connected synchronous Generator, the voltage drop through the neutral grounding resistor, R is equal to V3 10 R, where IO is the 2610 sequence current. ) Positive-Sequence and negative sequence currents cannot pass through the neutral grounding resistor in a wye.connected generator
Question:
In step 1 give the introduction of the concept and in step 2 give the correct answer and give its explanation seperately and in step 3 explain why the other options are not correct and give final answer
at last explain what we did in each step in just few sentences
use formula andcalculation for beter understanding
1) When the receiver in previous question is tured to 540 kHz station, what other AM station offers
potential interference?
285 kHz
1)995 kHz
©1060 kHz
d) 1450 kHz
2) An industrial plant is served by a 12470.v deta/430-v gronded-wye transformer. The high voltage ide of the
transformer is served from a 12470-v wye.connected distribution line that has a grounded neutral. The best
protection of th transformer against lightning strikes on the 12470.v ine il result from surge arrester
connections of
2) Phase to ground on the 12470-v ide of th transformer
b) Phase to phase on the 12470.v side ofthe transformer
©) Balise:to ground on the 430-v side of the transformer
) Phase to neutral to ground on the 430-v sce ofthe transformer
3) ASCADA system configuration regires maximum values (Le. the actual value of current when the transducer
is at full scale). The transducer ah a flscale ac current of 5A. Sing a current transformer it a ts ait of
40035. the maximum current value (amperes) is most nearly
a) 1200
b)800
400
4300
4) Whats the maximum allowable size of the over-current device normaly alowed to protect an AWG # 12.
THHW conductor rated for 90° sed in an ambient temperature of 55°C? Only standard size over —current
devices are available
a0
b)15
920
30
5) When using the method of symmetrical components , which of the following statements is most
nearly correct
2) The three zero.sequence current phasors are equal in magnitude and displaced by 1200
1b) The three positive=sequence and the three negative-sequence current phases are all equal in
‘mannitude_ but have opposite phase
©)In a wye-connected synchronous Generator, the voltage drop through the neutral grounding resistor, R
is equal to V3 10 R, where IO is the 2610 sequence current.
) Positive-Sequence and negative sequence currents cannot pass through the neutral grounding resistor
in a wye.connected generator