Let's break down the problem step by step as per your image and text. Since the image contains a structural platform plan, let's interpret and solve the key questions: --- ## **Given Data** - **Platform Dimensions:** 24 ft × 8 ft - **Spacing:** Girders and columns at 6 ft intervals - **Height:** 20 ft steel pipe post - **Loading:** 100 psf dead load + 100 psf live load = **200 psf total load** - **Lumber Allowables:** Fb = 800 psi, Fv = 120 psi, E = 1.2 × 10⁶ psi - **Use 2× planks (actual size: 1.5" × 7.25" for 2×8, 1.5" × 9.25" for 2×10, etc.)** - **Girder Top Flange is continuously supported** - **Use C = 1.5 for bending and deflection** - **Deflection limit: L/240** --- ## **1. What size 2" joists are required?** ### **Step 1: Find Joist Span and Tributary Width** - **Span = 6 ft** (distance between girders) - **Tributary Width = 2 ft** (distance between joists, typical for platforms) ### **Step 2: Calculate Load per Joist** - **Uniform Load per Area:** 200 psf × 2 ft = **400 plf** (pounds/linear foot) ### **Step 3: Maximum Moment and Shear** - **Maximum Moment (simple span):** \[ M_{max} = \frac{wL^2}{8} \] \[ M_{max} = \frac{400 \times 6^2}{8} = \frac{400 \times 36}{8} = 180 \, \text{lb-ft} = 21,600 \, \text{lb-in} \] - **Maximum Shear:** \[ V_{max} = \frac{wL}{2} = \frac{400 \times 6}{2} = 120 \, \text{lb} \] ### **Step 4: Section Properties for 2×8, 2×10, 2×12** - **2×8:** \(d = 7.25"\), \(b = 1.5"\) - **2×10:** \(d = 9.25"\), \(b = 1.5"\) - **2×12:** \(d = 11.25"\), \(b = 1.5"\) - **Section Modulus \(S\):** \[ S = \frac{b d^2}{6} \] - 2×8: \(S = \frac{1.5 \times 7.25^2}{6} = 13.17 \, \text{in}^3\) - 2×10: \(S = \frac{1.5 \times 9.25^2}{6} = 21.4 \, \text{in}^3\) - 2×12: \(S = \frac{1.5 \times 11.25^2}{6} = 31.6 \, \text{in}^3\) - **Allowable Bending Stress:** \(F_b = 800 \, \text{psi} \), but use adjusted value with \(C = 1.5\): \(F_{b,adj} = 800 \times 1.5 = 120 \, \text{psi}\) ### **Step 5: Required Section Modulus:** \[ S_{req} = \frac{M_{max}}{F_{b,adj}} \] \[ S_{req} = \frac{21,600}{120} = 18 \, \text{in}^3 \] - **2×8:** 13.17 < 18 (NG) - **2×10:** 21.4 > 18 (OK) - **2×12:** 31.6 > 18 (OK) **Use 2×10 joists (minimum).** --- ## **2. Is a continuous 2" plank adequate as the deck?** - **Span = 2 ft (between joists)** - **Load = 200 psf × 2 ft = 400 plf** - **Maximum Moment:** \[ M_{max} = \frac{400 \times 2^2}{8} = 200 \, \text{lb-ft} = 2,400 \, \text{lb-in} \] - **Section modulus for 2×8 plank:** 13.17 in³ - **Allowable Moment:** \[ M_{allow} = F_{b,adj} \times S = 120 \times 13.17 = 15,804 \, \text{lb-in} \] - **Required: 2,400 < 15,804** (OK) **Yes, a continuous 2" plank is adequate.** --- ## **3. Choose an economical W shape for the girders.** - **Span = 8 ft (between columns)** - **Tributary width = 6 ft (from joists)** - **Load = 200 psf × 6 ft = 1,200 plf** - **Maximum Moment:** \[ M_{max} = \frac{wL^2}{8} = \frac{1,200 \times 8^2}{8} = 9,600 \, \text{lb-ft} = 115,200 \, \text{lb-in} \] - **Steel Allowable Stress (typical):** 24 ksi - **Required S:** \[ S_{req} = \frac{115,200}{24,000} = 4.8 \, \text{in}^3 \] - **Common W shapes** (from AISC tables): - W8×10: S = 10.3 in³ (OK, economical) - W8×13: S = 13. in³ (OK) **Use W8×10 or W8×13 (check local availability and deflection).** --- ## **4. Choose an economical size for the pipe columns.** - **Load per column:** - Each girder supports (8 ft × 6 ft = 48 ft²) at each column - Total load: 48 ft² × 200 psf = 9,600 lb per column - **20 ft tall column, check slenderness:** - Slenderness limit: \( \frac{KL}{r} < 200 \) (for steel) - Use a pipe (e.g., 4" Sch 40; r ≈ 1.24 in) \[ \frac{20 \times 12}{1.24} = 193.5 < 200 \] - **Capacity (approximate):** 4" Sch 40 pipe > 10,000 lb (OK) **Use 4" Sch 40 steel pipe (verify actual load capacity with detailed column design).** --- ## **5. What is the platform’s maximum deflection? Is it less than L/240?** - **For joists (span = 6 ft = 72 in):** - \(L/240 = 72/240 = .3" \) - **Deflection for uniform load:** \[ \Delta_{max} = \frac{5 w L^4}{384 E I} \] - \(w = 400 \, \text{plf} = 33.3 \, \text{plf-in}\) - \(E = 1.2 \times 10^6 \, \text{psi}\) - \(I_{2x10} = \frac{1.5 \times 9.25^3}{12} = 98.9 \, \text{in}^4\) - \(L = 72 \, \text{in}\) \[ \Delta_{max} = \frac{5 \times 33.3 \times 72^4}{384 \times 1.2 \times 10^6 \times 98.9} \] \[ = \frac{5 \times 33.3 \times 26,873,856}{45,584,640,000} \] \[ = \frac{5 \times 33.3 \times 26,873,856}{45,584,640,000} = \frac{4,468,044}{45,584,640,000} = .098 \text{ in} \] - \(.098" < .3"\) (OK) --- ## **Summary Table** | Component | Selected Size | Adequacy | |---------------------|-----------------|-------------------------| | Joists | 2×10 | OK | | Deck Plank | 2" Dimensional | OK | | Girder | W8×10 | OK, check deflection | | Pipe Column | 4" Sch 40 | OK, check actual design | | Max Deflection | .098" | < L/240 (OK) | --- ## **Final Answers** 1. **Use 2×10 joists.** 2. **A continuous 2" plank is adequate for the deck.** 3. **Use an economical W8×10 (or similar) girder.** 4. **Use a 4" Sch 40 steel pipe for columns.** 5. **Maximum deflection is about .1", which is less than L/240 = .3".** --- If you need calculations for another element (like the girders' deflection or detailed steel checks), let me know!

📢 Instructions:

  • Ask anything relatd to above question only.
  • For new Question goto :

Study Help, Fast Answers

VIPSolutions focuses on clear, step‑by‑step explanations so you can learn quickly. Whether you need an AI‑generated walkthrough or a short hint to get unstuck, each solution is organized for fast reading and easy review later.

Search similar questions, compare approaches, and bookmark the best answers for revision. Our goal is simple: quick, reliable study help that feels natural—not noisy.