A process liquid comprising of heavy distillate paraffins is pumped at a flowrate of 6 0 ton / hr from a storage tank to a fractionator using a centrifugal pump. The pipeline is Nominal Size of 8 0 mm schedule 4 0 commercial steel pipe. The pipeline is 2 5 0 m long. Miscellaneous friction head losses including rapid contraction of liquid from tank into the pipeline as well as expansion from the pipe into the fractionator are equivalent to 5 0 0 pipe diameters. The storage tank operates at atmospheric pressure and the fractionator column at 2 bara. The lowest liquid level in the tank will be 2 m above the pump inlet, and the feed point to the column is 6 m above the pump inlet. Calculate the power required by the pump. Assume that the pump efficiency as 7 0 % . The properties of the liquid distillate are: Density 9 5 0 kg / m 3 Viscosity 1 . 0 mN m - 2 s Search Question On Google

Question:

A process liquid comprising of heavy distillate paraffins is pumped at a flowrate of 6 0 ton / hr from a storage tank to a fractionator using a centrifugal pump. The pipeline is Nominal Size of 8 0 mm schedule 4 0 commercial steel pipe. The pipeline is 2 5 0 m long. Miscellaneous friction head losses including rapid contraction of liquid from tank into the pipeline as well as expansion from the pipe into the fractionator are equivalent to 5 0 0 pipe diameters. The storage tank operates at atmospheric pressure and the fractionator column at 2 bara. The lowest liquid level in the tank will be 2 m above the pump inlet, and the feed point to the column is 6 m above the pump inlet. Calculate the power required by the pump. Assume that the pump efficiency as 7 0 % . The properties of the liquid distillate are: Density 9 5 0 kg / m 3 Viscosity 1 . 0 mN m - 2 s Search Question On Google

This is AI generated Response.
Asked by: Test User 100043
Created at: 2025-04-26 00:38:18

Final Answer:

Rendered Raw Text
Did you like this answer?
Let's break down the problem step by step: ### **Given Data** - **Flow rate (\(\dot{m}\))**: \(60\) ton/hr = \(60,000\) kg/hr = \(16.67\) kg/s - **Pipe Nominal Size**: 80 mm (Assume actual internal diameter for Sch 40 is about **ID = 77.9 mm = 0.0779 m**) - **Pipe length (L)**: 250 m - **Miscellaneous losses**: Equivalent to 500 pipe diameters - **Density (\(\rho\))**: 950 kg/m³ - **Viscosity (\(\mu\))**: 1.0 mN·m⁻²·s = 1.0 cP = 0.001 N·s/m² - **Tank pressure**: Atmospheric = 1.013 bar = 101,300 Pa - **Column pressure**: 2 bara = 200,000 Pa - **Tank level above pump**: 2 m - **Column feed point above pump**: 6 m - **Pump efficiency (\(\eta\))**: 70% = 0.7 --- ## **Step 1: Calculate Volumetric Flow Rate (\(Q\))** \[ Q = \frac{\dot{m}}{\rho} = \frac{16.67\ \text{kg/s}}{950\ \text{kg/m}^3} = 0.01755\ \text{m}^3/\text{s} \] --- ## **Step 2: Calculate Pipe Velocity (\(v\))** \[ A = \frac{\pi}{4} d^2 = \frac{\pi}{4} (0.0779)^2 = 0.00476\ \text{m}^2 \] \[ v = \frac{Q}{A} = \frac{0.01755}{0.00476} = 3.69\ \text{m/s} \] --- ## **Step 3: Calculate Reynolds Number (\(Re\))** \[ Re = \frac{\rho v d}{\mu} = \frac{950 \times 3.69 \times 0.0779}{0.001} = 272,900 \] (Turbulent flow) --- ## **Step 4: Friction Factor (\(f\))** For commercial steel pipe (assume roughness \(\epsilon = 0.046\) mm): \[ \frac{\epsilon}{d} = \frac{0.000046}{0.0779} = 0.00059 \] Using Colebrook or Swamee-Jain approximation: \[ f = 0.25 / [\log_{10}(\epsilon/3.7d + 5.74/Re^{0.9})]^2 \] \[ f = 0.25 / [\log_{10}(0.00059/3.7 + 5.74/(272900^{0.9}))]^2 \] Calculate: - \(0.00059/3.7 = 0.000159\) - \(272900^{0.9} \approx 48271\) - \(5.74/48271 = 0.000119\) - Sum: \(0.000159 + 0.000119 = 0.000278\) - \(\log_{10}(0.000278) = -3.555\) - \([ -3.555 ]^2 = 12.64\) - \(0.25 / 12.64 = 0.0198\) So **\(f \approx 0.02\)** --- ## **Step 5: Head Losses** ### **(a) Frictional Head Loss (Darcy-Weisbach)** \[ h_f = f \frac{L}{d} \frac{v^2}{2g} \] \[ \frac{L}{d} = \frac{250}{0.0779} = 3208 \] \[ \frac{v^2}{2g} = \frac{(3.69)^2}{2 \times 9.81} = \frac{13.61}{19.62} = 0.693\ \text{m} \] \[ h_{f,pipe} = 0.02 \times 3208 \times 0.693 = 44.5\ \text{m} \] ### **(b) Miscellaneous Losses** Equivalent to 500 pipe diameters: \[ L_{eq} = 500 \times 0.0779 = 38.95\ \text{m} \] \[ \frac{L}{d} = \frac{38.95}{0.0779} = 500 \] \[ h_{f,misc} = 0.02 \times 500 \times 0.693 = 6.93\ \text{m} \] ### **(c) Total Frictional Loss** \[ h_{f,total} = 44.5 + 6.93 = 51.43\ \text{m} \] --- ## **Step 6: Static Head** \[ \text{Static head (elevation)} = 6\ \text{m (column feed above pump)} - 2\ \text{m (tank above pump)} = 4\ \text{m} \] But actually, in pump calculations, the **static head** is the elevation difference between the source liquid level (2 m above pump) and the discharge point (6 m above pump): \[ \Delta z = 6\ \text{m} - 2\ \text{m} = 4\ \text{m} \] --- ## **Step 7: Pressure Head Difference** \[ \Delta P = P_{column} - P_{tank} = (200,000 - 101,300) = 98,700\ \text{Pa} \] \[ \text{Pressure head} = \frac{\Delta P}{\rho g} = \frac{98,700}{950 \times 9.81} = \frac{98,700}{9,319.5} = 10.6\ \text{m} \] --- ## **Step 8: **Total Head Required (\(H\))** \[ H = \text{Pressure head} + \text{Static head} + \text{Frictional head} \] \[ H = 10.6 + 4 + 51.43 = 66.03\ \text{m} \] --- ## **Step 9: Pump Power (Brake Power)** \[ \text{Pump Water Power} = \rho g Q H \] \[ = 950 \times 9.81 \times 0.01755 \times 66.03 = 10,788\ \text{W} = 10.79\ \text{kW} \] \[ \text{Pump Shaft Power} = \frac{\text{Pump Water Power}}{\text{Efficiency}} \] \[ = \frac{10,788}{0.7} = 15,411\ \text{W} = 15.4\ \text{kW} \] --- ### **Final Answer** **The required pump power is approximately \(15.4\) kW.** --- ### **Summary Table** | Quantity | Value | |------------------------|--------------| | Flow rate (\(Q\)) | 0.01755 m³/s | | Pipe velocity (\(v\)) | 3.69 m/s | | Reynolds number (\(Re\)) | 272,900 | | Friction factor (\(f\))| 0.02 | | Frictional head loss | 51.4 m | | Static head | 4 m | | Pressure head | 10.6 m | | **Total head (\(H\))** | **66 m** | | **Pump power** | **15.4 kW** | --- ### **Assumptions** - Pipe roughness as per commercial steel. - Sch 40 pipe internal diameter. - Minor losses as provided. - Negligible kinetic energy change at inlet/outlet. **If you need the step-by-step calculation in a spreadsheet or want to check pipe diameter, let me know!**

📢 Instructions:

  • Ask anything relatd to above question only.
  • For new Question goto :

Study Help, Fast Answers

VIPSolutions focuses on clear, step‑by‑step explanations so you can learn quickly. Whether you need an AI‑generated walkthrough or a short hint to get unstuck, each solution is organized for fast reading and easy review later.

Search similar questions, compare approaches, and bookmark the best answers for revision. Our goal is simple: quick, reliable study help that feels natural—not noisy.